Netvox Z803 Wireless Power Strip User Manual

The Z803 is a wireless power strip with power monitoring LCD and USB port. It can detect the current, voltage, power and energy of the load, and has the function of on/off control. The Z803 is used as a routing device in the network, allowing other devices to act as its sub-devices. The Z803 can be bound to a device with the Match Key function, and the Z803 switch can be controlled through the bound device, or it can be controlled through the switch on the Z803 device itself. The Z803 device LCD display can display the current, voltage, power and energy values of all loads of the device. Users can use the ZiG-BUTLER software to view the current current, voltage value, power and energy value of each output port and the total load.


Netvox Z803 Wireless Power Strip User Manual - cover page
Brand
netvox
Category
Socket
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
679 KB
Published
05 November, 2023
Updated
05 November, 2023
MD5 checksum
547C0D3B17D40712D2349543C5A5F452

About this manual

The Netvox Z803 is a wireless power strip with power monitoring LCD and USB port that functions as a ZigBee Simple Metering device and router. It measures current, voltage, power, and energy for connected loads and provides on/off control of four output sockets.

This manual describes installation, network joining, binding and unbinding, display switching, data reporting, and memory clearing. It also lists load characteristics, related products, installation environment, and maintenance instructions. This manual is written in Chinese.

What's inside

  • Declaration
  • Introduction
  • Appearance Diagram
  • Product Installation and Usage Steps
  • Load Characteristics
  • Related Products
  • Installation Method
  • Maintenance and Care

Specifications

Power inputAC 100-240V
Rated Load (AC) EU Type16A/250V ~
Rated Load (AC) UK Type13A/250V ~
Rated Load (AC) AU Type10A/250V ~
Rated Load (AC) US Type15A/125V ~
Max. Load with LEDsLED power less than 400W, less than 8 LEDs (each relay)
Max. Inductive Load (cos φ =0.4)8A/250V
Max. Load with Electric Motors1.5HP/250V

Frequently asked questions

What electrical values can the Z803 measure?

The Z803 can detect load current, voltage, power, and energy, and provides on/off control.

What is the rated AC load for the EU type Z803?

The EU type is rated at 16A/250V.

What is the rated AC load for the US type Z803?

The US type is rated at 15A/125V.

How long does the Z803 wait before disconnecting a load if current exceeds the measurement range?

It automatically disconnects the load within 2 秒 after detection.

Download PDF (679 KB)

More netvox Manuals


View all netvox manuals →