Netvox RA0715 Wireless CO2/Temperature/Humidity Sensor Datasheet

The Netvox RA0715 is a LoRa‑based wireless sensor that measures temperature, humidity and CO₂ with up to 10 km range.


Netvox RA0715 Wireless CO2/Temperature/Humidity Sensor Datasheet - cover page
Brand
netvox
Category
Other
Document type
Datasheet
Language
English
Pages
5
File format
PDF
File size
229 KB
Published
29 September, 2026
Updated
29 September, 2026
MD5 checksum
281C539FA2A57FE482C2CB4A8904D798

About this manual

The RA0715 wireless sensor combines a temperature‑humidity sensor and a CO₂ sensor in a single LoRa‑enabled device. It uses the SX1276 communication module and supports LoRaWAN frequency bands, allowing integration with platforms such as TTN, MyDevices, and Cayenne for smart‑home or smart‑farm applications.

Technical specifications include a 12 V DC power input, standby current of 125 mA, operating current of 40 mA, and a built‑in antenna providing up to 10 km line‑of‑sight range. The CO₂ sensor measures 400‑5000 ppm with ±100 ppm+6% accuracy, while temperature is measured from –20 °C to 55 °C with ±0.5 °C accuracy and humidity from 0 %RH to 100 %RH with ±4 %RH accuracy.

What's inside

  • Introduction
  • Main Features
  • Electrical Input Power
  • CO₂ Sensor Specifications
  • Temperature and Humidity Sensor
  • Frequency and Modulation
  • Antenna and Communication Distance
  • Physical Dimensions

Specifications

Input PowerDC 12 V / 1 A
Standby Current125 mA
Operating Current40 mA
CO₂ Sensor Voltage4.5 VDC – 5.5 VDC
CO₂ Sensor Accuracy±100 ppm + 6 % reading
CO₂ Measurement Range400 ppm – 5000 ppm
Temperature Range-20 °C – 55 °C
Temperature Accuracy±0.5 °C @25 °C, Max ±0.8 °C @-20 °C~55 °C
Humidity Range0 %RH – 100 %RH
Humidity Accuracy±4 %RH @25 °C
Frequency Bands863‑928 MHz, 470‑510 MHz
RX Sensitivity (LoRa)-136 dBm
Antenna TypeBuilt‑in antenna
Communication Distance10 km line‑of‑sight
Physical Dimensions117 mm × 114 mm × 41 mm

Frequently asked questions

What wireless technology does the RA0715 use?

It uses the SX1276 wireless communication module and supports LoRa technology.

What is the CO₂ measurement range of the sensor?

The CO₂ sensor measures concentrations from 400 ppm to 5000 ppm.

How can the sensor be configured or read remotely?

Configuration parameters can be set through third‑party software platforms, and data can be read and alarms set via SMS text and email (optional).

What is the maximum communication distance under ideal conditions?

Up to 10 km line‑of‑sight transmission distance.