The manual introduces the features, use methods and precautions of VICTOR 31005A/32005A/33030A/36020A DC power supplies
This is the Chinese user manual for the VICTOR 31005A/32005A/33030A/36020A single-output high-power DC regulated power supply. It opens with safety precautions and warning definitions, then gives a product overview describing the LED four-digit voltage and current display and a minimum current setting of 4 mA, and describes the front and rear panels: power switch, COARSE and FINE voltage and current knobs, CV and CC indicator lamps, output + and − terminals, GND terminal, OUTPUT lamp, fan window, AC input socket, fuse holder and input voltage selector.
The manual then lists rated operating conditions and technical specifications for constant-voltage and constant-current operation, followed by operating instructions and precautions (grounding, ventilation clearance, voltage and current presetting, 15-minute warm-up before measurement), a packing list and a maintenance/troubleshooting section covering a blown fuse, CC current protection and CV open-circuit voltage protection. Contact details for the seller in Shenzhen and the manufacturer in Xi'an are printed at the end. This manual is written in Chinese.
| Power supply voltage | AC 220 V ±5%, 50 Hz/60 Hz |
|---|---|
| Rated input power | ≤ 1500 W |
| Operating conditions | 0~40 °C, ≤80 %RH |
| Storage conditions | -10~70 °C, ≤80 %RH |
| Voltage display accuracy | ≤0.5% + 5 digits |
| Current accuracy | ≤0.5%+5 digits (below 20 A); ≤1%+5 digits (20 A and above) |
| Ripple and noise (CV) | ≤2 mVrms (5 Hz–1 MHz) |
| Recovery time | ≤100 ms (50 % load change, minimum load 0.5 A) |
| Temperature coefficient | ≤300 ppm/°C |
| Voltage display resolution | 10 mV (33030A/36020A), 100 mV (31005A/32005A) |
| Current display resolution | 10 mA (33030A/36020A), 1 mA (31005A/32005A) |
| Insulation resistance | ≥20 MΩ between chassis and output terminals; ≥30 MΩ between chassis and power cord (at DC 500 V) |
| Minimum current setting | 4 mA |
It operates from AC 220 V ±5% at 50 Hz or 60 Hz, with a rated input power of no more than 1500 W.
It has a four-digit LED display for both voltage and current, plus CV and CC working-status indicator lamps.
One complete unit, one power cord, one user manual and one power output cable.
The manual states the unit should be switched on and warmed up for 15 minutes before its technical specifications are measured.