About this manual

The document is a Cornell Dubilier application guide for aluminum SMT capacitors. It presents case dimensions and an outline drawing, reflow soldering temperature profiles by case code, tape and reel specifications, land patterns, and component orientation.

It also covers cleaning and coating guidance for V-Chips, including recommended cleaning agents, the reaction of free chlorine with aluminum, solvents that should not be used, and a notice and disclaimer.

What's inside

  • Case Dimensions
  • Outline Drawing
  • Reflow Soldering Temperature Profile
  • Tape Specifications
  • Component Orientation
  • Reel Specifications
  • Land Pattern
  • Cleaning
  • Reaction of Free-chlorine and Aluminum
  • Coating

Specifications

Case code A diameter and length3.0 mm diameter, 5.4 mm length
Case code P diameter and length16.0 mm diameter, 16.5 mm length
Reflow peak temperature and time at 200 °C for case codes A, B, C, D, X240 °C peak; 40 seconds maximum at 200 °C
Reflow peak temperature and time at 200 °C for case codes E, F, G, H230 °C peak; 30 seconds maximum at 200 °C
Reel size for case codes A and B380 ±2.0 mm
Tape width for case code A12.0 mm
V-Chip immersion time in Level 1 and 2 solvents5 minutes
Cleaning agents to avoidChlorine-based halogenated cleaning solvents, adhesives and coating agents

Frequently asked questions

Can V-Chips be immersed in cleaning solvents?

Yes. V-Chips may be immersed safely for 5 minutes in Level 1 and 2 solvents.

Which cleaning solvents should not be used?

Do not use chlorine-based halogenated cleaning solvents, adhesives or coating agents.

What peak reflow temperature applies to case codes A, B, C, D, and X?

The peak temperature is 240 °C, with a maximum of 40 seconds at 200 °C.

What should be done after cleaning to avoid solvent residue?

Make sure the assembly is dried thoroughly after cleaning.