Maxwell Anchormax V1 and V2 Service Manual

Maxwell Anchormax Service Manual. Including Anchormate and Anchormax V1-V2 two generations of maintenance manual


Maxwell Anchormax V1 and V2 Service Manual - cover page
Brand
Maxwell
Category
Other
Document type
Service Manual
Language
English
Pages
13
File format
PDF
File size
2.5 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
E7D3D42E556518B56056A4E0156801A4

About this manual

This service manual from Maxwell covers the Anchormax drum units, including the earlier Anchormate design and the Anchormax V1 (mid 1999 to January 2011) and Anchormax V2 (January 2011 to present). It explains the design changes between versions and gives service instructions for all models, including disassembly of the baseplate and deckplate and removal of the drum and gear assemblies.

The manual also lists yearly service recommendations for the V1 and V2, such as checking current draw, seals, bushes and bearings, and gives a step-by-step procedure for servicing the motor, including inspection of the armature, magnets and brushes. Exploded drawings of the Anchormate, Anchormax V1 and Anchormax V2 are included at the back of the booklet, together with notes pages.

What's inside

  • History
  • Anchormate
  • Anchormax V1
  • Anchormax V2
  • Service All Models
  • Yearly Service recommendations
  • Motor Service
  • Exploded Drawings
  • Notes

Specifications

Current draw at 12 V (Anchormax V1)No more than 25 A
Current draw at 12 V (Anchormax V2)No more than 35 A
Drum bore diameter (Anchormate)Ø42 mm
Drum bore diameter (Anchormax V1)Ø44.2 mm
Standard brush length12.7 mm
Motor change on Anchormax V2From 600 W (SP2142) to 500 W (SP4189)

Frequently asked questions

What current draw should an Anchormax V2 have at 12 V?

Running the unit in both directions, the current draw at 12 V should be no more than 35 A.

What is the standard brush length?

The standard brush length is 12.7 mm; the brushes should be checked for wear during motor service.

Can the original 600 W motor be replaced?

The original 600 W motor (SP2142) is no longer stocked, so it must be replaced by the 500 W motor (SP4189) together with adaptor kit P104725.

Why should the motor not be clamped in a vice?

Clamping the motor in a vice, or impact to the motor, will dislodge the magnets.