This file is a health care file, which is a technical guide on the treatment of temperature-sensitive flexible endoscopes.
This document is a technical guide annexed to an official French instruction (N° DGOS/PF2/DGS/VSS1/2016/220) issued by the Ministry of Health. It serves as a reference for professionals regarding the treatment of flexible endoscopes with channels that are sensitive to heat, specifically those that cannot be autoclaved. The guide outlines the unique regulatory framework replacing previous circulars and establishes the standard for good practices in healthcare establishments. This manual is written in French.
The retention period is 20 years, as fixed by the interministerial order of March 11, 1968.
The results of microbiological controls must be kept for 5 years at the analysis laboratory.
A high-level disinfection is mandatory immediately before use for all critical endoscopes used in surgery and penetrating sterile cavities.