Siemens CVCC 7ML19981FG01 Current Voltage Communication Converter Instruction Manual

This document is the CVCC CURRENTVOLTAGE COMMUNICATION CONVERTER instruction manual


Siemens CVCC 7ML19981FG01 Current Voltage Communication Converter Instruction Manual - cover page
Brand
Siemens
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
504 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
8B18452DA0DB82AAA347B66F78D90243

About this manual

This manual provides installation and operational instructions for the Siemens CVCC 7ML19981FG01, a communication converter that interfaces Milltronics equipment with customer computers via RS-232C or RS-422. It details power requirements, wiring, and jumper configurations for proper operation. Safety guidelines and visual indicators (LEDs) are also covered to ensure safe and correct usage.

The device supports 20 mA bipolar current loop communication and includes specifications for operating temperature, weight, and enclosure dimensions. Installation involves connecting data links, setting power jumpers, and flipping the power switch. Diagrams and terminal layouts are provided for RS-232 and RS-422 configurations.

What's inside

  • Safety Guidelines
  • Installation
  • Interconnection (RS-232)
  • Interconnection (RS-422)
  • Specifications

Specifications

Power115/230 Vac, 50 VA, 50/60 Hz - std. / 100/200 Vac, 50 VA, 50-60 Hz - special
Fuse1 A, MDL slo-blo or equivalent
Communication20 mA bipolar current loop, bidirectional - cable: Belden 9552, two pair shielded twisted, 18 ga. / RS-232C, bidirectional - cable: Belden 9552, two pair shielded/twisted, 18 ga. - cable length: 15 m (50 ft) maximum / RS-422, bidirectional - cable: Belden 9553, three pair shielded/twisted 18 ga. - cable length: 15 m (50 ft) maximum
Operating Temperature-20 to 60°C (-5 to 140°F)
Weight2.7 kg (5 lb)
Enclosure Dimensions203 mm (8") W x 254 mm (10") D x 84 mm (3.3") H

Frequently asked questions

What power supply does the CVCC 7ML19981FG01 require?

It requires 115/230 Vac, 50 VA, 50/60 Hz (standard) or 100/200 Vac, 50 VA, 50-60 Hz (special).

What is the operating temperature range?

The device operates between -20°C to 60°C (-5°F to 140°F).

What is the weight of the CVCC 7ML19981FG01?

It weighs 2.7 kg (5 lb).

Download PDF (504 KB)

More Siemens Manuals