The file is Data Logger C 70 Manual manual, which introduces the functions and usage methods of the product in detail
The Bosch C 70 is a programmable data logger for motorsport applications. Additional input devices can be connected via Ethernet and CAN buses, and the unit is configured with the RaceCon system configuration tool.
Its technical data include a 667 MHz dual-core application processor, 4 GB of standard internal logger memory with an optional additional 4 GB, and 4 analog and 4 speed inputs as standard with 12 more analog inputs available as an optional upgrade. The manual covers topics such as CAN configuration, analog and frequency inputs, recording, lap triggering, GPS, telemetry, firmware, and cloning.
| Application processor | 667 MHz Dual Core |
|---|---|
| Converters | 10 kHz 12 bit AD converters with digital low pass filter |
| Internal power source | Li/Ion capacitor |
| Standard internal logger memory | 4 GB |
| Optional internal logger memory | 4 GB |
| Internal logger channels | 1,500 |
| Sampling rate | 1 ms |
| Logging rate, all features | 600 kB/s |
| Logging rate, primary use case | >1,200 kB/s |
| Logging data download rate | up to 6.2 MB/s |
| Size | 151 x 126 x 25.5 mm |
| Weight | 450 g |
| Protection classification | IP54 to DIN 40050, Section 9, Issue 2008 |
| Operating temperature, internal | -20 to 85°C |
| Maximum vibration | Vibration profile 1 |
| Supply voltage | 5 to 18 V |
| Analog inputs | 4 standard, 12 optional |
| Analog input range | 0 to 5 V |
| Analog resolution | 12 bit |
| Wheel speed inputs | 4 x Hall-effect or DF11, switchable |
| Sensor supplies | 2 x 5 V, 1 x 10 V, 1 x U_Bat |
| CAN interfaces | 2 |
| Ethernet | 100BaseT, 2 |
| Laptrigger input | 1 |
| RS232 | Telemetry, GPS |
| Second logging partition upgrade | 1 GB |
| Data analysis software | WinDarab, free of charge |
| USB data copy | optional |
The C 70 is configured with the RaceCon system configuration tool.
WinDarab is available free of charge as WinDarab V7 free.
Yes, it can be upgraded to a second logging partition of 1 GB.
The protection classification is IP54 to DIN 40050, Section 9, Issue 2008.