This document is the user guide of D-series CoE Drive, which mainly introduces EtherCAT communication protocol, physical dimensions, object dictionary table, communication architecture, state machine, PDO mapping, synchronization mode, drive mode, touch probe function and so on.
This is version 1.0 (March 2014) of the Drive User Guide for the D-series CoE Drive, covering the D1NCOE, D1COE and D2COE EtherCAT drives. It starts with the EtherCAT communication specification and the physical dimensions of each drive model, then presents the object dictionary tables: data types, common objects, PDO mapping objects, sync manager communication objects, CiA402 objects and manufacturer defined objects.
The guide explains the communication architecture of the EtherCAT drive, the EtherCAT and CiA402 state machines, PDO mapping and synchronization modes, and the drive's modes of operation (profile and cyclic synchronization position mode, velocity, torque and homing), followed by the touch probe function. Appendices give step-by-step procedures for connecting to and operating the drive in position mode with TwinCAT, processing dynamic PDO mapping, and setting the EtherCAT operation mode.
| Communication standards | IEC 61158 Type 12; IEC 61800-7 CiA402 Drive Profile |
|---|---|
| Physical layer | 100BASE-TX (IEEE 802.3) |
| SyncManager | SM0 mailbox output, SM1 mailbox input, SM2 process data outputs, SM3 process data inputs |
| Process data | Dynamic PDO mapping |
| Synchronization | Free run; DC mode with DC cycle 250us, 500us, 1ms, 2ms or 4ms |
| Vendor ID (0x1018 sub-index 0x01) | 0x0000AAAA |
| Target torque range (0x6071) | -1000 to 1000 |
The drive follows IEC 61158 Type 12 and the IEC 61800-7 CiA402 drive profile, with a 100BASE-TX physical layer.
Free run and DC mode are supported; the DC cycle can be 250us, 500us, 1ms, 2ms or 4ms.
The vendor ID at index 0x1018 sub-index 0x01 is 0x0000AAAA.
No. The Home and Set buttons are deactivated because homing mode is already defined in the CiA402 standard, so the built-in homing procedures are not available.