A concise guide for diagnosing and resolving common alarm codes on Weihong Weizhi servo drives.
This document, published by Weihong Electronic Technology, provides step‑by‑step troubleshooting procedures for the most frequent alarm codes (e.g., Err120, Err130, Err140, Err160, Err760) that can occur on the Weizhi servo system. Each alarm section lists the cause, voltage or current thresholds, and a flow‑chart style decision tree to isolate the fault.
The guide also includes special case analyses, wiring recommendations, and a set of supplemental notes for complex issues such as encoder communication errors and motor‑brake interactions. It is intended for service technicians and system integrators who need quick, reliable diagnostics for machine tool applications. This manual is written in Chinese.
| PN voltage upper limit (Err120) | 420 V |
|---|---|
| PN voltage lower limit (Err130) | 180 V |
| Input voltage threshold (Err120) | 260 V |
| Line‑to‑line voltage (R/S/T) | 380 V |
| Line‑to‑line voltage (L1/L2/L3) | 220 V |
Verify the motor speed is above 10 rpm, check the torque command, and adjust the stall‑over‑temperature time window (Pr661). Follow the same steps as for Err160 if needed.