VICTOR 3900 Lightning Protection Standard Resistor User Manual

victor3900 is a special standard resistor for lightning protection. It is composed of 9 1/2w high-precision military-grade wire-wound resistors. It can be directly switched to test the resistance when calibrating the resistance. It does not need to change the test line. It has stable performance, sturdy structure, and convenient calibration testing.


VICTOR 3900 Lightning Protection Standard Resistor User Manual - cover page
Brand
Victor
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
685 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
BBF4B0576556AB0C4685ECD1C18C8AE7

About this manual

VICTOR 3900 is a lightning protection standard resistor used to calibrate ground resistance testers and equipotential testers. It consists of nine 1/2 W high-precision military-grade wirewound resistors and provides resistance values from 0.001 Ω to 100 kΩ.

The manual describes its technical specifications, instrument structure, operating method, and packing list. It states that calibration must use the four-wire method and that the resistor must not be subjected to more than 1/2 W. This manual is written in Chinese.

What's inside

  • Notes
  • Introduction
  • Technical specifications
  • Instrument structure
  • Operating method
  • Packing list

Specifications

FunctionCalibration of ground resistance testers and equipotential testers
Construction9 high-precision military-grade 1/2 W wirewound resistors
Resistance ranges and accuracy0.001 Ω (2%), 0.01 Ω (0.5%), 0.1 Ω (0.2%), 1.0 Ω (0.2%), 10 Ω (0.05%), 100 Ω (0.05%), 1 kΩ (0.05%), 10 kΩ (0.05%), 100 kΩ (0.05%)
Connection methodFour-wire method
Temperature coefficient±25 ppm
Dimensions173 mm x 125 mm x 70 mm
Mass360 g
Test leadsRed 0.5 m and black 0.5 m, 2 each
Operating temperature and humidity-10 to 40 °C; below 70% RH
Storage temperature and humidity-20 to 60 °C; below 80% RH
Insulation resistanceAbove 10 MΩ (circuit to housing, 500 V)
Withstand voltageAC 3700 V/rms (circuit to housing)
Safety complianceIEC 61010-1, CAT III 600 V, pollution degree, JJG166-1993

Frequently asked questions

What connection method must be used when calibrating with this standard resistor?

Calibration must use the four-wire method; otherwise measurement accuracy cannot be guaranteed.

What is the maximum power that may be applied to the resistor?

Do not apply more than 1/2 W, or the standard resistor may be damaged.

What items are included in the packing list?

The packing list includes one instrument, four test leads, one instrument bag, and one user manual with warranty card and certificate.