PCE PCE-CS 1000N Crane Scale User Manual

This is the user manual for the PCE-CS 1000N crane scale, which introduces the product's features and usage methods, and is suitable for all users of this product.


PCE PCE-CS 1000N Crane Scale User Manual - cover page
Brand
PCE
Category
Other
Document type
User Manual
Language
Spanish
Pages
13
File format
PDF
File size
1.6 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
2D383943F90BE0197F002E686173A0D7

About this manual

The PCE-CS 1000N is a crane scale for internal weight control with a maximum measuring range of 1,000 kg. It is powered by three AA batteries that provide up to 65 hours of operation, and it is supplied with hooks, shackles, and a remote control.

The manual describes safety information, technical specifications, device and remote-control parts, operating steps for power, zero, tare, hold, and unit changes, device settings, troubleshooting, special configuration, calibration, and disposal. Regular inspection and maintenance intervals are also stated. This manual is written in Spanish.

What's inside

  • Introduction
  • Safety information
  • Specifications
  • Device description
  • Operating instructions
  • Device settings
  • Troubleshooting
  • Special configuration
  • Calibration
  • Disposal

Specifications

Measurement range1,000 kg
Resolution200 g
Minimum load10 kg
Deviation±1% of the measuring range
Tare range100% F.s.
Response time≥1 second
Safety load150%
DisplayLCD with backlight
Power supply3 x AA 1.5 V batteries
WeightApprox. 1.4 kg including batteries, hook and shackle

Frequently asked questions

What is the maximum measuring range of the PCE-CS 1000N?

The maximum measuring range is 1,000 kg.

How long does the crane scale operate on batteries?

With three AA batteries, it can operate for up to 65 hours.

Can the device be switched on with the remote control?

No. The device cannot be turned on with the remote control; the remote control can switch it off.

What happens if the value is not stable during zeroing?

If the value is not stable, "Err" appears and the scale does not zero.

Download PDF (1.6 MB)