Instruction manual for the PCE-VS 10 vibration analyser sensor switch covering parametrization, installation, alarm settings and technical data.
This instruction manual describes the PCE-VS 10 vibration switch, an instrument for monitoring vibration on rotating machines, for example within preventive maintenance to DIN/ISO 10816, and for use as a limit switch for processes involving vibration and shock. An inbuilt piezoelectric accelerometer measures vibration perpendicular to the lid of the casing, and a digital signal processor with a relay output signals alarm status via green and red LEDs.
The manual explains parametrization with the PC software VS1x over a micro USB cable, including driver installation, gain, filter and integrator selection, warning and alarm limits, the teach-in factor and the relay switch output settings. It also covers mechanical installation, power supply connection, LED alarm indication and the technical data of the device.
| Measuring Range | 0.1 to 1000 m/s² acceleration, velocity frequency dependent |
|---|---|
| Monitoring Values | Peak value and RMS value of vibration acceleration or vibration velocity |
| High Pass Filter | 0.1/2/5/10/20/50/100/200/500/1000 Hz (acceleration); 2/5/10/20/50 Hz (velocity) |
| Low Pass Filter | 0.1/0.2/0.5/1/2/5/10 kHz (acceleration); 1 kHz (velocity) |
| Relay Output | PhotoMOS relay; SPST; max. 60 V / 0.5 A (AC/DC); open/close programmable |
| Alarm Delay / Hold Time | 0 – 99 s / 0 – 9 s |
| USB Connection | USB 2.0 full speed, CDC mode, micro USB socket |
| Power Supply | 5 to 30 V DC; < 100 mA via screw terminals or USB supply voltage |
| Protection Grade | IP67 |
| Operating Temperature Range | -40 – 80 °C |
| Weight | 160 g |
| Dimensions | 50 mm Ø, 52 mm height |
| Mounting | M8 thread pin; 8 mm length; coupling surface Ø 25 mm |
Unscrew the four socket head screws and remove the lid; the USB connector is inside, and the connection is made with a common micro USB cable.
All LEDs green means no warning or alarm, two red and two green means the warning limit has been exceeded, and all red means the alarm limit has been exceeded.
The power supply is 5 to 30 V DC with less than 100 mA, connected to the 0V and +U screw terminals, and it is protected against reverse polarity.
It is mounted vertically or horizontally, preferably with the supplied M8 screw, tightened by hand without a tool, on rigid components such as cast iron cases or bearing houses.