The document is an installation manual for a valve actuator.
This two-page Rotork instruction covers installation of the RCEL003 electric valve actuator. It describes mounting the actuator on the valve, electric wiring, adjustment of limit switch cams, and manual operation. The text includes a warning to remove power before removing the cover and states that electric wiring must be carried out by qualified personnel only.
The installation steps require the valve and actuator to be in the same fully open or fully closed position before assembly and the stems to be centered and aligned. Wiring is connected according to the enclosed diagram or the diagram shown, and the actuator is test run to check direction and limit switches. Manual operation uses the Auto-Manual selector and a 6 mm Allen key.
| Manual operation tool | 6 mm Allen key |
|---|---|
| Manual override direction | Clockwise to close, anti-clockwise to open |
| Closed-position cam markings | CLS and ACLS |
| Open-position cam markings | OLS and AOLS |
They must be in the same mode, fully open or fully closed, before assembly.
Electric wiring must be carried out by qualified personnel only.
Pull the Auto-Manual selector to Manual, use the attached 6 mm Allen key, turn clockwise to close and anti-clockwise to open.
Remove power before the cover is dismantled.