Rotork Gears AB, 232 and 300 Series Gearbox Installation and Operating Manual

This is a manual for installation and operating for gearbox model AB, 232 and 300.


Rotork Gears AB, 232 and 300 Series Gearbox Installation and Operating Manual - cover page
Brand
Rotork
Category
Other
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
131 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
3C51D49B31DBAD11E42C7F988AA78264

About this manual

This is the Rotork Gears BV manual for installation and operating of the AB-, 232- and 300-series quarter turn gearboxes, intended for the manual operation of valves such as butterfly and ball valves in pipelines. It is dated 2010-rev.01 and states that it is valid only for the standard gearboxes of these series, since special versions can differ in specifications and model.

The manual gives connection data and maximum allowable input and output torques in a table, handling and safety precautions including storage and disposal, and an ATEX section. It then describes mounting the gearbox to the valve, adjustment of the setscrews, operating instructions by handwheel, and maintenance, including the number of handwheel turns needed to fully open or close each gearbox type.

What's inside

  • Preface and technical data
  • Handling and safety precautions
  • ATEX
  • Installation: mounting to the valve
  • Adjustment of the setscrews
  • Operating instructions
  • Maintenance

Specifications

AB housing materialCast iron
232 housing materialAluminium
300 range housing materialStainless steel
Maximum torque AB 15016 Nm input / 150 Nm output
Maximum torque AB 210/215 (LB)28.5/43 Nm input / 330/500 Nm output
Ambient temperature range-20 to +120 °C
Protection class, 300 and 232 rangeIP65 (dust tight and water jet proof)
Protection class, AB range "N" gearboxIP67 (dust tight and temporary immersion proof)
Seal materialNitrile
ATEX markingII 2 G D c 120 C

Frequently asked questions

Does the gearbox need maintenance?

Under normal conditions the gearbox is maintenance free. It can be used at ambient temperatures from -20 to +120 °C.

Which way do I turn the handwheel to open the valve?

Turn the handwheel counter clockwise to open the valve and clockwise to close it. A special version with the reverse direction can be delivered.

Can I clean the gearbox with a high pressure water jet?

Only the standard "N" gearbox of the AB range, which reaches IP67, may be cleaned with a high pressure water jet. The standard 300 and 232 gearbox is IP65 and can be cleaned with a water hose, not a high pressure water jet.

Is a fixation needed to retain the valve position?

No, the gearbox is self-braking, so no fixation needs to be installed to retain the valve position.

Download PDF (131 KB)

More Rotork Manuals