This manual introduces the concept of lentivirus, its storage, dilution, use and precautions. It is suitable for the related experiments of lentivirus particles
This GeneCopoeia user manual describes how to use GeneCopoeia lentivirus particles for cell infection experiments. It gives a short overview of lentiviral vectors and the optimized HIV-backbone third-generation system, then explains storage, thawing and dilution of the particles, safety precautions and lab handling rules, preparation before an experiment, and the calculation of lentivirus volume from titer (TU/mL) and MOI.
The manual also walks through a pilot infection experiment in a 24-well plate with 293T or H1299 tool cells, provides tables of medium and virus volumes by plate format and an MOI optimization example for H1299 cells, lists which culture plates suit fluorescence, qPCR and Western Blot detection, and closes with FAQs and appendices on titer re-check and cell MOI reference values. This manual is written in Chinese.
| Recommended storage temperature | -80 °C |
|---|---|
| Storage life at -80 °C | about 6-12 months |
| Short-term storage | 4 °C, use within 3 days |
| Titer unit | TU/mL (Transduction Units per mL) |
| Titer loss per freeze-thaw cycle | about 50% |
| Packaging volume | 50 uL per tube (25 uL for control particles) |
| Recommended cell confluency at seeding | 20-30% |
Store them at -80 °C, where they generally keep for about 6-12 months. If they must be used immediately, keep the amount needed at 4 °C and use it within 3 days.
Each freeze-thaw cycle reduces the titer by about 50%, so repeated freezing and thawing should be avoided.
12-16 hours after infection, remove the medium containing lentivirus particles and add medium with 5% inactivated FBS to continue culturing.
Divide the number of cells exposed to lentivirus multiplied by the MOI by the lentivirus titer in TU/mL to get the volume in mL.