The Autonics MD5-HF14-AO microstep 5-phase stepper motor driver is a bipolar constant current five-phase drive mode, with automatic current reduction, self-diagnosis and other functions, and adopts optical coupling input insulation to reduce external interference. The microstep drive mode, which realizes low-speed rotation and ultra-precision control, is a product.
This document is the Chinese product manual for the Autonics MD5-HF14-AO Series microstepping 5-phase stepper motor driver. It covers safety precautions, main features, usage precautions, product contents, specifications, function settings, alarm display and output functions, input/output circuits and wiring examples, troubleshooting, and part names.
The manual states a bipolar constant-current 5-phase drive method, microstepping up to 250 divisions, automatic current-down and self-diagnosis functions, and photo-coupler inputs. It also lists electrical and environmental specifications such as 100-220 VAC power, 0.4-1.4 A/phase drive current, and 0-50°C operating temperature. This manual is written in Chinese.
| Model | MD5-HF14-AO |
|---|---|
| Power supply voltage | 100-220 VAC, 50/60 Hz ±10% |
| Maximum current consumption | 3 A |
| Drive current | 0.4-1.4 A/phase |
| Stop current | 27-90% of drive current |
| Drive method | Bipolar constant-current 5-phase |
| Basic step angle | 0.72° |
| Microstep division ratios | 1, 2, 4, 5, 8, 10, 16, 20, 25, 40, 50, 80, 100, 125, 200, 250 |
| Pulse width | CW/CCW ≥1 μs; HOLD OFF ≥1 ms |
| Duty rate | 50% (CW/CCW) |
| Pulse input voltage | H: 4-8 VDC; L: 0-0.5 VDC |
| Pulse input current | 7-14 mA (CW/CCW); 10-16 mA (HOLD OFF) |
| Maximum input pulse frequency | ≤500 kHz (CW/CCW) |
| Input impedance | 270 Ω (CW/CCW); 390 Ω (HOLD OFF); 100 Ω (ALARM) |
| Insulation resistance | ≥100 MΩ (500 VDC) |
| Withstand voltage | 1000 VAC, 50/60 Hz, 1 minute |
| Noise immunity | ±2000 V square-wave noise, 1 μs |
| Vibration | 5-60 Hz, 1.5 mm amplitude, 2 hours |
| Operating temperature | 0-50°C; storage -10 to 60°C |
| Operating humidity | 5-65% RH; storage 35-85% RH |
| Weight (with packaging) | ≤660 g |
It requires 100-220 VAC at 50/60 Hz ±10%.
The drive current can be set from 0.4 to 1.4 A per phase.
The listed division ratios include 1, 2, 4, 5, 8, 10, 16, 20, 25, 40, 50, 80, 100, 125, 200, and 250.
The maximum input pulse frequency is 500 kHz for CW/CCW.