Heat flow path temperature controller user manual, introduces the basic structure, use methods, precautions, technical specifications of the temperature controller
This document is the user manual for a heat runner temperature controller designed for high-precision PID temperature regulation. The device supports multiple control modes including Normal, Standby, Manual, and Auto-tuning (AT), utilizing thermocouples (J, K, or E type) for input signals. It features a compact 3D box design and includes a control card with a detailed operation panel. This manual is written in Chinese.
| Power Input Voltage | AC85V~250V, 50/60Hz, 20A |
|---|---|
| Temperature Sensor Type | J or K or E type thermocouple |
| Temperature Setting Range | 0~450℃ (32~842℉) |
| Temperature Measurement Error | ± 0.5% |
| Control Output Type | Triac Voltage Control (PWM) or Triac Power Control (SSR) |
| Output Load Capacity | 20A, 50~2200W (110V) or 100~4400W (220V) |
| Operating Ambient Temperature | 0~55℃ (32~131℉) |
The controller supports J, K, or E type thermocouples for temperature measurement.
The available modes are Normal (PID control), Standby, Manual, and AT (Auto-tuning).
Enter the Engineer Menu by inputting '2' in the SV display window while in the LCK input state and pressing the SET key.