ACD2000 is a miniature CO2 sensor that uses advanced photoacoustic spectroscopy to accurately measure the concentration of CO2 in the air. ACD2000 integrates photoacoustic detection technology, precision optical path and high-precision signal detection circuit, with excellent performance, good selectivity, no oxygen dependence, long life and other advantages; small size can be quickly integrated into customer's products, convenient for product development.
The ACD2000 is a compact photoacoustic CO2 sensor based on infrared absorption technology. It offers high precision, long-term stability, and no oxygen dependency. The manual details its working principle, technical specifications, calibration methods, and I2C/UART communication protocols for integration into various applications.
The sensor supports automatic and manual calibration modes, with commands for setting calibration values, resetting factory defaults, and reading software version and sensor ID. It operates on 4.75–5.25V, has a measurement range of 400–5000ppm, and outputs data via I2C or UART at 3.3V logic levels. This manual is written in Chinese.
| Working Voltage | 4.75~5.25V |
|---|---|
| Working Current | Average current <25mA |
| Measurement Range | 400~5000ppm (customizable) |
| Accuracy | ±(50ppm + 5% of reading) |
| Output Interface | I2C/UART (3.3V logic) |
| Warm-up Time | 120 seconds |
| Operating Conditions | 0~50℃; 0~95%RH (non-condensing) |
| Storage Conditions | -40~70℃; 0~95%RH (non-condensing) |
| Data Refresh Rate | 2 seconds |
| Lifespan | Over 5 years |
The measurement range is 400–5000ppm, with customization available for larger ranges.
It supports both I2C and UART communication protocols with 3.3V logic levels.
The sensor requires 120 seconds to warm up before stable readings are available.
It performs automatic calibration every 7 days (168 hours) after the initial 24-hour calibration upon power-up.