This manual introduces the characteristics of the Siemens SITRANS F M MAGFLO series electromagnetic flowmeters, including models, sizes, connection methods, pressure, temperature, lining, electrodes, housing, explosion-proof version, and output.
This handbook provides technical documentation for the complete range of SITRANS F M MAGFLO electromagnetic flowmeters, including sensor types MAG 1100, MAG 3100, and MAG 5100 W, and transmitter types MAG 5000 and MAG 6000. The document details the product introduction, mode of operation based on Faraday's law, and specific features such as the SENSORPROM memory unit and USM II communication modules.
| Flow direction | Uni/bidirectional |
|---|---|
| Meter uncertainty | ±0,5% o.r. |
| Input impedance | >10 14 Ω |
| Turn down ratio | minimum 3000:1 |
| Power supply (MAG 5000/6000) | 12-24 V AC/DC |
The new transmitter uploads all previous settings stored in the SENSORPROM unit and resumes measurement without any need for re-programming.
These flowmeters are designed for measuring all electrically conductive liquids.
The device allows flow measurements on fluids with conductivities as low as 1 mS/cm.
The transmitter has a turn down ratio of minimum 3000:1.