TE Connectivity AAL-Series Inclinometer Module Instruction Manual

This is an instruction manual for AAL-Series Inclinometer Module.


TE Connectivity AAL-Series Inclinometer Module Instruction Manual - cover page
Brand
TE Connectivity
Category
sensor
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
602 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
B06298297A6FDDAA868C7988B9384BC5

About this manual

The TE Connectivity AAL-Series is an inclinometer module that uses a liquid/conductive measurement principle. The instruction manual covers the functional block diagram, typical output signal, part numbers, specifications, terminal connections, and signal definitions.

The manual also documents the on-board EEPROM contents and register maps for the NS-2/AAL2-UDD, NS-5/AAL2-UDD, NS-10/AAL2-UDG, NS-15/AAL2-UDG, and NS-30/AAL2-UDN versions. Calibration information is stored in the on-board EEPROM so users can linearize the output signal with their own software. Start-up code, continuous angle calculation, and a sample application are included.

What's inside

  • General Information
  • Liquid/conductive measurement principle
  • Typical output signal
  • Part Number
  • Specification
  • Terminal Connection and Signal Definition
  • EEPROM Contents
  • Start-Up Code
  • Continuous Angle Calculating
  • Sample Application

Specifications

Measurement range (each axis)±2°, ±5°, ±10°, ±15°, ±30° versions
Supply voltage4.75 V to 5.25 V
Operating temperature range-40 °C to +85 °C
Typical attainable system resolution±0.04°
Reference voltage2.4 V to 2.6 V
Output voltage X- and Y-axis0.3 V to VCC − 0.3 V
Maximum output bandwidth3 Hz

Frequently asked questions

What measurement range does the NS-30/AAL2-UDN version cover?

The NS-30/AAL2-UDN version covers -30° to +30°.

What supply voltage does the AAL-Series require?

VCC must be between 4.75 V and 5.25 V with reference to GND.

Where is the calibration information stored?

The AAL-Series keeps calibration information inside the on-board EEPROM, allowing the output signal to be linearized with the user's own software.

What is the typical attainable system resolution?

The manual states a typical attainable system resolution of ±0.04°.