3M Clean-Trace Hygiene Management System is a hygiene management system for environmental surfaces that uses ATP bioluminescent monitoring technology to help healthcare facilities manage environmental surface cleanliness and reduce patient infection risk.
The 3M Clean-Trace Hygiene Management System for Environmental Surfaces Hygiene Management Guide outlines the steps necessary to set up and implement an effective ATP hygiene monitoring program within a healthcare environment. It explains ATP bioluminescent monitoring technology and how the Clean-Trace ATP Surface Test and NGi Luminometer measure surface cleanliness in Relative Light Units.
The document describes the 3M Recommended Monitoring Plan with tiered approaches for education, competency, terminal cleaning verification, and high-risk area monitoring. It also covers test point selection, pass/fail thresholds, testing frequency, data collection, metrics, corrective actions, and continuous improvement.
| Measurement unit | Relative Light Units (RLUs) |
|---|---|
| Test time | less than 30 seconds |
| Tier 1 pass threshold | ≤250 RLUs |
It measures levels of ATP present on an environmental surface to indicate organic contamination or biological contamination.
The test can be performed in less than 30 seconds, providing a real-time result.
Staff should achieve a pass of ≤250 RLUs on 16 out of 20 touch points, or 80% pass.
The system includes 3M Clean-Trace Online Software for capturing results, auto-analysis, and auto-generation of reports.