Anderson Instrument Co. MPF Modular Pressure Transmitter Instruction Manual

This document is the instruction manual for the Anderson Instrument Co. Inc. MPF modular pressure transmitter.


Anderson Instrument Co. MPF Modular Pressure Transmitter Instruction Manual - cover page
Brand
Anderson Instrument Co.
Category
pressure transmitters
Document type
User Manual
Language
English
Pages
29
File format
PDF
File size
1.3 MB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
1A6A966D10D8FCE4E71455C272929556

About this manual

This manual provides detailed instructions for installing, wiring, configuring, calibrating, and maintaining the Anderson Instrument Co. MPF modular pressure transmitter. It covers technical specifications, sensor and instrument wiring, modular assembly, configuration options with or without a display, calibration procedures including zero and range adjustments, and diagnostic maintenance. The device is designed for food, beverage, pharmaceutical, and chemical industries and features a modular design with replaceable electronic puck and sensor stem. Safety warnings and environmental specifications are included to ensure proper use and prevent damage or injury.

What's inside

  • Introduction
  • Theory of Operation, Description and Intended Use
  • Installation
  • Sensor Wiring
  • Instrument Wiring
  • Modular Assembly
  • Configuration
  • Calibration
  • Maintenance/Diagnostics
  • HART Communicator Connection & DD Menu Structure

Specifications

Calibrated Accuracy± 0.10% of calibrated range up to 5:1 turndown (± 0.15% if over 5:1 turndown)
Response Time<100 Milliseconds
Sampling Rate<50 Milliseconds
Over-Range Capability30/100/500 psi stem: 1.5x URL no effect on accuracy 2x URL to failure
Process Temperature Limits0 to 350°F (-18 to 177°C) with ambient temperatures to 140°F (60°C) and 0 to 330°F (0 to 71°C) with ambient temperatures to 160°F (71°C)
Ambient Temperature Limits32 to 160°F (0 to 71°C)
Enclosure ProtectionDesigned and factory tested to NEMA 4X & IP66; (IP69K when equipped with QDR)
Internal FillETR (Extended Temperature Range) FDA approved mineral oil, Optional Neobee 20®
Output2 wire user selectable 4-20 mA DC or 20-4 mA Optional - HART 7.0 digital communications protocol
Operating Voltage24 (18-36 VDC) regulated or unregulated

Frequently asked questions

What is the calibrated accuracy of the MPF transmitter?

± 0.10% of calibrated range up to 5:1 turndown (± 0.15% if over 5:1 turndown).

What is the over-range capability for the 30/100/500 psi stem?

1.5x URL no effect on accuracy, 2x URL to failure.

What are the process and ambient temperature limits?

Process: 0 to 350°F (-18 to 177°C) with ambient to 140°F (60°C) or 0 to 330°F (0 to 71°C) with ambient to 160°F (71°C). Ambient: 32 to 160°F (0 to 71°C).

What is the output signal type?

2 wire user selectable 4-20 mA DC or 20-4 mA, with optional HART 7.0 digital communications protocol.

Download PDF (1.3 MB)

More Anderson Instrument Co. Manuals