This is the instruction manual for the HMP series turbine flowmeters produced by Anderson Instrument Co. Inc.
This manual provides detailed instructions for installing, wiring, calibrating, maintaining, and troubleshooting the HMP Turbine Flowmeter. It includes specifications, installation guidelines, electrical wiring diagrams, calibration procedures, maintenance steps, and a troubleshooting guide. The flowmeter is designed for accurate volumetric measurement of liquids in industrial applications, with features such as stainless steel construction and a sealed probe for durability in wet environments.
| Supply Voltage (HTS1000) | 8-24 VDC |
|---|---|
| Signal Output (HTS1000) | 7.3-23.3 VDC, Unscaled, Pulsed Output |
| Ambient Temperature Range (HTS1000) | -40° - 79°C (-40 - 175°F) |
| Accuracy | +0.50% of rate Over Entire Flow Range |
| Maximum Product Temperature | 149°C (300°F) |
| Maximum Inlet Pressure | 10.3 Bar (150 psi) |
| Maximum Product Viscosity | 100 cps |
| Housing Material | 316L Stainless Steel (Ra20 max) |
| Rotor Material | 316L Stainless Steel (Ra20 max) |
| Gasket Material | PTFE Polytetrafluoroethylene |
| Bearing Sleeve Material | Rulon® 123 (reinforced Polytetrafluoroethylene) |
| Adhesive | GSP 1325-2 (Epoxy Resin) |
| Process Connection | Sanitary Clamp Connections |
| Compliance | ASME BPE-2004 3-A compliant, Third party verified in accordance with standard 28-03 |
The K-Factor is the number of pulses the meter outputs per a fixed volume, typically labeled as 'P/G' (pulses per gallon) on the meter body.
The maximum product temperature is 149°C (300°F).