About this manual

This instruction manual provides detailed guidance for installing, wiring, configuring, calibrating, and maintaining the Anderson Instrument Co. AIC2075 MPP modular pressure transmitter. It covers sensor and instrument wiring, loop power, modular assembly, configuration options including HART and Foundation Fieldbus, calibration procedures, and diagnostic tools. The device is designed for accurate pressure measurement in life sciences applications with NEMA 4X/IP67 protection and modular, field-replaceable components.

The manual includes specifications for performance, environmental limits, construction materials, and operational parameters. It also provides diagrams for installation and wiring, and explains how to perform zero and span calibration, set alarms, and use the display interface. Maintenance and diagnostic procedures are outlined in Section 9, and communication protocols for HART and Foundation Fieldbus are detailed in Sections 10 and 11.

What's inside

  • Introduction
  • Theory of Operation and Description
  • Installation
  • Sensor Wiring
  • Instrument Wiring
  • Modular Assembly
  • Configuration
  • Calibration
  • Maintenance/Diagnostics
  • HART Communicator Connection & DD Menu Structure

Specifications

Calibrated Accuracy± 0.07% of calibrated range up to 5:1 turndown (± 0.10% if over 5:1 turndown)
Repeatability0.05% as calibrated
Long Term Stability0.2% URL for 2 years
Process Temperature Effect± 0.1 psi/10°F (5.5°C) typical
Ambient Temperature Effect± 0.1 psi/10°F (5.5°C) typical
Over-Range Capability30/100/500 psi stem: 1.5x URL no effect on accuracy 2x URL to failure 1000 psi stem: 1.1x URL no effect on accuracy 1.25x URL to failure
Response Time<100 Milliseconds
Sampling Rate<50 Milliseconds
Range Turndown Capability10 to 1 turn down from URL Ranges
Process Temperature Limits0 to 350°F (-18 to 177°C) with ambient temperatures to 140°F (60°C) and 0 to 330°F (0 to 71°C) with ambient temperatures to 160°F (71°C)
Ambient Temperature Limits32 to 160°F (0 to 71°C)
Enclosure ProtectionNEMA 4X & IP67 IP69K(when equipped with QDR)
Product Contact Material316L Electropolished and finished to a Max. Ra <8 microinches. Optional: Hastelloy® diaphragm
Non-Product Contact Metal316L & 304 finished to a Max. Ra <32 microinches and polished to a high gloss
Non-Product Contact Plasticpolycarbonate threaded cap. Delrin atmospheric vent
Wiring ConnectionM16 x 1.5 threaded housing electrical entry Equipped with: Standard - replaceable M12 5 pin Eurofast QDR Optional - M16 Cord Grip, M16 x 1.5" NPTF adaptor, Minifast 7/8” 4pin
Internal FillETR (Extended Temperature Range) FDA approved mineral oil, Optional Neobee 20®
Output2 wire user selectable 4-20 mA DC or 20-4 mA HART 7.0 digital communications protocol, or Foundation Fieldbus
Internal Display4 digit LED nominally displays loop current. Process variable selectable - PSI or BAR.
Display InterfaceModular, Field replaceable. 5-digit LED, 170 field of view, Analog bar graph, configurable visible alarm alerts, Selectable display units - Millibar, Torr & Kg/cm2, PSI, BAR, kPA, In H2O, In Hg, mm H2O, mA
Loop Resistance0-300 ohms at 24 VDC
Operating Voltage18-36 VDC (24 VDC Nominal regulated or unregulated)
Zero Adjustmentone touch
Re-SpanWith switch through user interface & with or without a reference pressure source
Electronics PuckModular, field replaceable
Fitting & Sensor StemModular, field replaceable
Warranty2 years

Frequently asked questions

What is the accuracy of the MPP Modular Pressure Transmitter?

Calibrated Accuracy: ± 0.07% of calibrated range up to 5:1 turndown (± 0.10% if over 5:1 turndown).

What are the environmental limits for the transmitter?

Process Temperature Limits: 0 to 350°F (-18 to 177°C) with ambient temperatures to 140°F (60°C) and 0 to 330°F (0 to 71°C) with ambient temperatures to 160°F (71°C). Ambient Temperature Limits: 32 to 160°F (0 to 71°C).

What is the output signal type?

2 wire user selectable 4-20 mA DC or 20-4 mA HART 7.0 digital communications protocol, or Foundation Fieldbus.

How is the transmitter protected against moisture?

Units equipped with M12 Quick Disconnects are rated to NEMA 4X and IP69X. Cable gland equipped units are rated to NEMA 4X and IP67.