The manual contains the information necessary for the correct use of the Force Control 7.0.
This document provides detailed reference information for the Epson RC+ 7.0 Option Force Control 7.0, including properties, statuses, and commands for force control operations. It covers robot control, force object, mass property, and coordinate conversion commands. The manual also includes safety precautions, warranty information, and usage guidelines for proper operation and maintenance.
The document is structured with a table of contents listing sections such as Force Control 7.0 Command Table, Robot Control Related Commands, Force Object Related Commands, and more. It includes detailed descriptions of properties like Tx_TargetForce, Ty_TargetForce, Tz_TargetForce, and their usage with examples. The manual also explains how to set and retrieve values for force control parameters and how to handle force control operations with virtual coefficients of elasticity, viscosity, and inertia.
The Force Control 7.0 is used to control the force and torque applied by the robot during operations.
The target torque values are specified in units of [mN·m] and can range from the rated negative detection capability to the rated positive detection capability of the force sensor.
Use the FSet statement with the object name and the target torque value for the specified axis.
The robot operates while following the external force because it moves so that the force becomes "0".