This is a user manual of EA04 electric actuator, which introduces the characteristics, specifications and usage methods of EA04 electric actuator.
This document provides installation, operating, and maintenance instructions for the Georg Fischer EA04 electric actuator. It includes wiring diagrams for AC and DC power, specifications such as torque and voltage ratings, and details on manual override and limit switches. The actuator is designed for use with Type 104 actuated valves and features an IP65 housing and integrated position indicator.
The manual emphasizes safety, recommending qualified electricians for installation and warning against over-tightening or removing the cover without authorization. It also explains how to operate the actuator using continuous live signals and how to reset the electronic torque limiter if torque exceeds rated output.
| Nominal Torque | 10 Nm |
|---|---|
| Peak Torque | 12 Nm |
| Control Time | 18 seconds/90º at Mdn 10% without load |
| Actuating Angle | 90°-180° |
| Rated Voltage | 80-240V, 50/60 Hz AC |
| Rated Output | 21 Watts |
| Duty Cycle | ED 35% at 77°F/15 min |
| Protection Class | IP 65 |
| Weight | 3.3 Pounds |
| Operating Temperature | 14° to 110°F |
The rated voltage is 80-240V, 50/60 Hz AC.
Supply a continuous live signal to operate the actuator; it will rotate until the cams operate the micro switch and cut the power to the motor.
Cut the power, clear the cause of the excess torque (e.g., valve blockage), turn the power back on, and the limiter will reset.
No, use the auxiliary limit switches for position indication. The power terminals should not be used for position indication.