This document is the user manual of PERMA PURE FF-250™ Series Filter
This user manual explains how to install and operate the Perma Pure FF-250™ Series Filter for either particulate-only or coalescing and particulate filtration. It details the filter’s operation, including how liquid droplets and particles are removed down to 0.1 micron with 95% efficiency. The manual also provides step-by-step instructions for replacing the filter element and lists part numbers for replacement components.
Technical specifications include materials (316 SST or Kynar® shell, borosilicate glass), maximum temperature (120°C for Kynar, 230°C for SST), maximum pressure (30 PSIG), and dimensions (2.5" dia. x 4.0" h). Installation diagrams and pressure drop curves are included for reference.
| Maximum Temperature | 120°C (Kynar®), 230°C (SST) |
|---|---|
| Maximum Pressure | 30 PSIG |
| Dimensions | 2.5" dia. X 4.0" h |
| Inlet/Outlet/Drain Ports | 1/8" NPT Female |
The filter removes particles down to 0.1 micron with 95% or greater efficiency.
The shell is made of 316 SST or Kynar®, and the filter element is made of thick borosilicate glass and Teflon®.