2” AND 3” LP DISC-KLEEN FILTER
This guide provides detailed instructions for operating, maintaining, and troubleshooting Philips 2" and 3" LP DISC-KLEEN filters. It includes specifications, installation steps, backflush procedures, and system maintenance. The filters are designed for agricultural and landscape applications, filtering water through stacked discs with color-coded micron ratings. Backflushing is automated via solenoid valves controlled by a backflush controller, with settings adjustable for local water conditions.
The document also covers filter dimensions, water quality classifications, maximum flow rates, and materials used (polypropylene, nylon, EPDM seals). Installation requires correct inlet/outlet orientation, proper solenoid wiring, and drainage line connections. Maintenance includes regular backflush cycles and checking for damage before operation.
| Minimum Operating Pressure | 20 psi |
|---|---|
| Maximum Operating Pressure | 90 psi (Standard Model) |
| Minimum Backflush Flow Rate (2" Filter) | 35 GPM |
| Minimum Allowable pH | 5 |
| Inlet and Outlet Connections (2" Filter) | 4" Grooved |
| Backflush Valve Material | Reinforced Polyamide |
| Filter Disc Mesh Sizes | 40, 80, 120, 140, 200 micron |
Minimum Operating Pressure: 20 psi.
Manifold: Polypropylene; Filter Body and Cover: Polypropylene; Filter Spine: Nylon; Discs: Polypropylene; Backflush Valve: Plastic with reinforced polyamide; O-Rings and Seals: EPDM.
Backflushing should be maintained for 20 seconds.
Maximum flow rate is 180 GPM.