Molecular Devices GxP Admin Software Version3.0.1 User Guide

This is a user guide for GxP Admin software. The software can manage Molecular Devices equipment, software, reagents and consumables.


Molecular Devices GxP Admin Software Version3.0.1 User Guide - cover page
Brand
Molecular Devices
Category
Healthcare software
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
7.1 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
4133317861E2B8BE7CB3187B5C8C2187

About this manual

This user guide explains how to use the GxP Admin Software version 3.0.1, which manages user access, document workflows, and audit trails for GxP-compliant laboratories using SoftMax Pro GxP Software. It details how to create users, assign roles and permissions, manage projects, and monitor system activity through the System Audit Trail. The software stores data in a secure Microsoft SQL database and enforces compliance with FDA 21 CFR Part 11 guidelines.

The guide also covers software installation, user login procedures, document status workflows (In Work, Review Pending, Reviewed, Released, etc.), and maintenance settings. It specifies compatibility requirements: version 3.0.1 requires SoftMax Pro GxP Software version 7.1.1 or later, and is not backward compatible with earlier versions.

What's inside

  • Introduction
  • Software Installation
  • Getting Started
  • Home
  • Users
  • Roles
  • Projects
  • Maintenance
  • System Audit Trail
  • Logging In to SoftMax Pro Software - GxP Edition

Specifications

Software VersionVersion3.0.1
Database TypeMicrosoft SQL database
CompatibilitySoftMax Pro GxP Software version 7.1.1 or later
Compliance StandardsFDA 21 CFR Part 11, GMP, GLP

Frequently asked questions

What software is this guide for?

This guide is for the GxP Admin Software version 3.0.1, which manages user access and audit trails for GxP-compliant labs using SoftMax Pro GxP Software.

What is the minimum SoftMax Pro GxP Software version required?

SoftMax Pro GxP Software version 7.1.1 or later is required for compatibility with GxP Admin Software version 3.0.1.

Can documents be edited in SoftMax Pro Standard edition?

No, documents created by SoftMax Pro GxP Software cannot be opened or modified in the Standard edition to ensure FDA 21 CFR Part 11 compliance.

What is the purpose of the System Audit Trail?

The System Audit Trail records over 140 events including document changes, instrument settings, user activities, and file modifications to ensure compliance with FDA 21 CFR Part 11.