About this manual

This user manual provides instructions for the Philips regulated linear DC power supply models, including the HY1503D, HY1803D, GPS-1850D, and others. Designed for laboratory, school, and manufacturing applications, these units feature excellent ripple and load regulation, allowing them to function as constant voltage or constant current sources. They are suitable for applications such as electroplating, anodizing, battery charging, and DC motor testing.

What's inside

  • Introduction
  • Specifications
  • Front Panel Descriptions
  • Back Panel
  • Technical Parameters
  • Installation
  • Operation Instructions
  • Constant Voltage Operations
  • Constant Current Operation
  • Battery Charging Operation

Specifications

AC Input110V/220V±10%, 47-63 Hz
Operating Temperature-10°C to 40°C
Ripple & noise (Max. current <3A)< 0.5mVrms (5Hz-1MHz)
Line regulation (CV mode)<0.01%+3mV
Load regulation (CV mode, Max. current<3A)< 0.01%+3mV
Display accuracy±1%±1 digit

Frequently asked questions

What are the applications for these power supplies?

They are suitable for laboratory, school and manufacturing applications, including electroplating, anodizing, battery charging, and DC motor testing.

How do I select the input AC voltage?

Use the AC voltage selector switch on the back panel to select either 110V or 220V. The switch must be set correctly before plugging in the power cord.

What happens when the power supply is in CC mode?

The CC indicator light turns red, and the power supply operates in constant current mode where the output current remains constant.