Introduces the use of 25HBC5, 25HCE4 single-stage heat pumps
This document provides installation instructions for Carrier 25HBC5 and 25HCE4 single-stage heat pumps operating with Puron refrigerant. It covers safety considerations, equipment inspection, and site preparation requirements. The guide details proper mounting, clearance, and refrigerant line installation procedures for residential applications.
| Cooling Mode Minimum Outdoor Operating Ambient | 55°F (12.78°C) |
|---|---|
| Cooling Mode Maximum Outdoor Operating Ambient | 125°F (51.67°C) |
| Heating Mode Maximum Outdoor Operating Ambient | 66°F (18.89°C) |
| Maximum Liquid-Line Size | 3/8-in. OD |
| Unit Leveling Tolerance | +2° (+3/8 in/ft,£9.5 mm/m) |
| Clearance to Service End | 24 in. (609.6 mm) |
| Clearance Above Unit | 48 in. (1219.2 mm) |
| Refrigerant Type | Puron |
The minimum outdoor operating ambient in cooling mode without an accessory is 55°F (12.78°C).
The maximum outdoor operating ambient in heating mode is 66°F (18.89°C).
The maximum liquid-line size is 3/8-inch OD for all residential applications, including long lines.