This is a safety manual for TORRIX … & VISY-Stick … 44 799 13752002.
This safety manual provides guidelines for the safe use, installation, and maintenance of FAFNIR’s TORRIX and VISY-Stick level sensors. It details safe operating conditions, mounting procedures, diagnostic error codes, and safety parameters such as SIL 2 certification and failure rates. The manual also covers interface protocols (HART, RS485, TAG) and troubleshooting for different sensor models.
The document is intended for technicians and installers ensuring compliance with EN 61508 standards. It includes technical specifications, error handling, and safety ratings for various sensor configurations, including temperature ranges and mechanical structures. This manual is written in Italian.
| Safety Integrity Level | SIL 2 |
|---|---|
| Temperature Range - HT | -40 °C … +250 °C |
| Temperature Range - LT | -65 °C … +125 °C |
| Hardware Fault Tolerance | HFT = 0 |
| Average Dangerous Failure Rate (PFH) | λDU (varies by model) |
| Mean Time to Repair (MTTR) | 8 h |
The sensors are designed for SIL 2 applications according to EN 61508.
The second byte of the sensor response contains device status, including flags like 'Device Malfunction' (0x80, Bit 7) and 'More Status Available' (0x10, bit 4).
The mean time to repair is 8 hours.