TORRIX … & VISY-Stick … 44 799 13752002 Safety Manual

This is the safety manual of TORRIX … & VISY-Stick … 44 799 13752002, which mainly introduces the safety characteristics of the product. It is suitable for use in security subsystems with a safety level of SIL 2


TORRIX … & VISY-Stick … 44 799 13752002 Safety Manual - cover page
Brand
FAFNIR
Category
Industrial Robot
Document type
Service Manual
Language
French
Pages
5
File format
PDF
File size
184 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
1DE461208B95D3FFB2E9EA2152CDB54D

About this manual

This document is a safety manual for FAFNIR TORRIX and VISY-Stick series magnetostrictive level sensors. It details the application domain, specifically for safety systems conforming to the EN 61508 SIL 2 standard. The manual covers various sensor types, including those for biodiesel, ethanol, LPG, and interstitial monitoring, and specifies hardware and software version requirements for safe operation. This manual is written in French.

What's inside

  • Domaine d'application
  • Normes
  • Codification des types
  • Montage et démontage
  • Installation
  • Mise en service
  • Maintenance
  • Caractéristiques techniques relatives à la sécurité

Specifications

Safety Integrity LevelSIL 2
Mean Time To Repair8 hours
Safety Test Interval1 year
Architecture1001

Frequently asked questions

What safety standard do these sensors comply with?

The sensors are designed for safety systems conforming to the EN 61508 SIL 2 standard.

What is the minimum hardware version required for this manual?

This manual applies to all level sensors starting from hardware version 4.

How long does it take to reach the safety state in case of an error?

The safety state is reached within ten seconds when an error is detected.