This safety manual specifies the safe use of TORRIX … and VISY-Stick …
This safety manual covers the use, installation, and maintenance of FAFNIR’s TORRIX and VISY-Stick level sensors, which are designed for safety-related applications per EN 61508:2010. It specifies hardware and firmware version requirements, installation procedures, and diagnostic error handling for different sensor interfaces including HART, RS485, SC, TAG, and TLS. The document also details safety-related codes, failure rates, and recovery times for SIL 2 compliance.
| Safety Integrity Level | SIL 2 |
|---|---|
| Hardware Fault Tolerance | HFT = 0 |
| Failure Rate (λDU) | 1.38E-07 h⁻¹ (TORRIX…) |
| Mean Time to Recovery | 8 h |
| Retest Interval | 1 year |
The level sensors are designed in accordance with EN 61508:2010, all parts Functional safety of electrical/electronic/programmable electronic safety-related systems.
This safety manual applies to all level sensors from hardware version 4 and from firmware version 4.9 upwards.
In the event of a detected error, the sensor outputs an error value (safe state) and reaches the safe state within ten seconds.
The second data byte of the level sensor response contains the device status. The flag "Device malfunction" (0x80, bit 7) signals a device error.