This manual describes the specifications, design, product description, commissioning, maintenance and cleaning for the testo 6610 probes.
This manual provides instructions for installing, commissioning, and maintaining Testo 6610 probes used with testo 6383 transmitters. It covers probe types including digital, humidity, heated cable, and self-monitoring variants. Sections detail probe specifications, design, accessories, and how to replace filters or sensors. It also includes guidance on using the P2A software for parameterizing and analyzing the transmitter.
The manual explains probe accuracy, temperature ranges, and ordering options for different probe versions and accessories, including protection caps and cable lengths.
| Humidity Range | 0 to 100 % RH |
|---|---|
| Temperature Range | -20 to +70 °C/-4 to +158 °F |
| Accuracy | ± (1.0 % RH + 0.007 x reading) for 0 to 90 % RH |
| Probe Type | Digital probes |
No, the humidity sensor cannot be exchanged by the customer except for the testo 6611 model.
The testo 6614 probe has a temperature range of -70 to +180 °C/-94 to +356 °F.