The document is the instruction manual of Cognex In-Sight 5000 Series Vision System Manual
This document serves as the user manual for the Cognex In-Sight 5000 Series Vision System. It outlines critical safety precautions, regulatory compliance information, and installation procedures for various models within the series, including the 5100, 5400, 5600, 5700, and 5800 families. The guide emphasizes proper power supply specifications and cable management to ensure safe operation.
| Power Supply Requirement | 24VDC output rated for at least 600 mA |
|---|---|
| Maximum Short Circuit Current | less than 8A |
| Maximum Power Rating | less than 100VA |
| Power Class | Class 2 or Limited Power Source (LPS) |
| FCC Classification | Part 15, class A |
The system must be supplied by a UL or NRTL listed power supply with a 24VDC output rated for at least 600 mA.
No, the system does not contain user-serviceable parts, and making modifications may void the warranty.
The bend radius must be at least six inches from the connector.