This document is the user manual for AiC-CL series Closed-Loop Stepper System. It introduces the product's features and characteristics, usage instructions, installation and maintenance, etc.
The document is a comprehensive user manual for the Autonics AiC-CL Series Closed-Loop Stepper System. It covers essential information including product symbols, detailed safety considerations regarding installation and operation, and specific cautions during use such as wiring requirements and environmental conditions.
The guide also includes technical specifications, parameter settings, connection diagrams, and a troubleshooting section to help users resolve common malfunctions like communication errors or motor drive instability.
| Power Supply Input | 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device. |
|---|---|
| Power Connector Wire Gauge | AWG18 |
| Motor+Encoder Connector Wire Gauge | AWG22, AWG24 |
| I/O Connector Wire Gauge | AWG28 |
If the servo is not ON, the excitation of the motor will be released.
This occurs when the MotorDir parameter setting is not correct.