This manual introduces the safe use and precautions of the 2831E and 5491B digital multimeters.
This manual provides operating instructions for the B&K Precision 2831E (4½ digit) and 5491B (50,000 count) bench multimeters. It covers safety precautions, front and rear panel descriptions, and basic measurement functions including voltage, current, resistance, frequency, and diode testing. The document also details advanced features such as math functions, limit operations, and remote control via USB and RS232 interfaces using SCPI commands.
| DC Voltage Basic Accuracy (5491B) | 0.02% |
|---|---|
| DC Voltage Basic Accuracy (2831E) | 0.03% |
| Maximum Measurement Rate | 25 readings/sec |
| DC Voltage Range | up to 1000 V |
| AC Voltage Range | up to 750 V |
| DC Current Range | up to 20 A |
| AC Current Range | up to 20 A |
| Resistance Range (2831E) | up to 20 MΩ |
| Resistance Range (5491B) | up to 50 MΩ |
| Frequency Range | 10 Hz to 1 MHz |
The meters provide a maximum measurement rate of 25 readings/sec.
Yes, the meters are programmable via USB (Virtual COM) interface using SCPI commands.