BW Technologies GP-MBUS4 MODBUS Expansion Module Installation and Setup Instructions

This document is an installation manual that introduces the installation, wiring, MODBUS protocol and other information of the BW GasPoint Expansion Module GP-MBUS4.


BW Technologies GP-MBUS4 MODBUS Expansion Module Installation and Setup Instructions - cover page
Brand
BW Technologies
Document type
Installation Guide
Language
English
Pages
19
File format
PDF
File size
192 KB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
8A92328DDAEB26A63CFCEF1BCB336B04

About this manual

The BW GasPoint MODBUS Expansion Module is an optional add-on card designed for the 12-bit version of the BW GasPoint. It enables the monitor to interface with a MODBUS system using a suitable controller as a master device. The module is fully compatible with BW GasPoint Monitors having serial numbers starting with '3-' or higher.

What's inside

  • General Description
  • Manufacturer's Notes and Warnings
  • Specifications
  • Installation
  • Switch Configuration
  • Wiring
  • A Guide to Cable Selection
  • MODBUS Protocol

Specifications

Communications ProtocolMODBUS RTU slave
Baud rates1200, 2400, 9600, 19200 bps field selectable
Word length8 bits
Electrical interfaceRS 485
Duplex modeHalf Duplex (2 or 4 wire field selectable)
MODBUS addressable range1-247
Max devices on network32
Supported Function Codes3, 5, 6, and 7
Power SupplyPowered by BW GasPoint
Power Consumption<70 mA @ 24 VDC

Frequently asked questions

What is the default baud rate for the GP-MBUS4?

The default baud rate setting is 9600 bps.

What is the default parity configuration?

The default configuration is even parity with one stop bit.

Is extra power wiring required for installation?

No, the module is powered directly by the BW GasPoint unit.

What are the supported MODBUS function codes?

The module supports function codes 3, 5, 6, and 7.