BW Technologies GasAlertMicro Quick Reference Guide

A quick reference guide for the BW Technologies GasAlertMicro portable gas detector, covering safety information, operation, calibration, and specifications.


BW Technologies GasAlertMicro Quick Reference Guide - cover page
Brand
BW Technologies
Document type
Quick Start Guide
Language
English
Pages
19
File format
PDF
File size
572 KB
Published
19 October, 2026
Updated
19 October, 2026
MD5 checksum
D6845039FF953B9D99C5CEDAE13DAC12

About this manual

This document serves as a quick reference guide for the BW Technologies GasAlertMicro portable gas detector. It provides essential information on using the device to detect hazardous gases such as Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), and combustible gases. The guide emphasizes that while it offers basic instructions, users should refer to the full user manual on the included CD for complete operating procedures.

What's inside

  • GasAlertMicro Introduction
  • Safety Information
  • Components of GasAlertMicro
  • Display Items Explanation
  • Button Functions
  • Installing Batteries and Starting Device
  • Calibration Procedures
  • Connecting the Cylinder
  • Specifications

Specifications

Dimensions6 x 10 x 3.3 cm (2.4 x 4.0 x 1.3 inches)
Weight211 g (7.4 oz)
Operating Temperature-20°C to +50°C (-4ºF to +122ºF)
Humidity Range5% to 95% relative humidity (no condensation)
CO Measurement Range0-500 ppm
H2S/SO2 Measurement Range0-100 ppm
Oxygen Measurement Range0-30%
Combustible Gas Range0-100% LEL or 0-5.0% v/v methane
Battery Life (Alkaline)16-18 hours

Frequently asked questions

How often should the detector be calibrated?

BW recommends calibrating at least every 180 days (6 months) based on usage and sensor exposure.

What is the recommended procedure for a daily sensor check?

Perform an 'impact test' by exposing the sensor to gas concentrations exceeding the high alarm point before use.

What happens if the reading exceeds the range?

If a reading exceeds the range, it indicates that gas concentration may be approaching explosive levels.

Where should batteries not be changed or charged?

Batteries should never be replaced or charged in hazardous areas to avoid weakening safety and causing fire or explosion.