This manual describes the operation and maintenance of IntelliHeat™ power sources.
This document is the Operation and Maintenance Manual for PACE IntelliHeat™ Power Sources. It provides instructions for setting up, operating, and maintaining various models of the system, which combines Tip Heater Cartridge (THC) technology with SensaTemp handpieces. The guide covers both analog and digital temperature controlled power supplies.
| Tip Heater Cartridge Temperature Range | 205 to 455°C (400 to 850°F) nominal |
|---|---|
| SensaTemp Handpieces Temperature Range | 37 to 482°C (100 to 900°F) nominal |
| Digital Readout Resolution | ±5° (°C or °F) |
| Tip Temperature Stability at Idle | ±1.1°C (2°F) from Set Tip Temperature |
| Vacuum Rise Time | 150 ms average |
| Maximum Vacuum (ST 65, ST 75 & ST 115) | 20 in. Hg. |
| Maximum Pressure Setting | (18 P.S.I.) |
Repair procedures should be performed by Qualified Service Personnel only.
Domestic models operate on 97 to 127 VAC at 50/60Hz.
The recommended shop air pressure is 5.48 Bar or 80 P.S.I.
The nominal tip temperature range is 37 to 482°C or 100 to 900°F.