Product manual, introducing the features and usage of Switch-Pak™ w/ Compact Relay Controller AU13, AV13 & AZ13 Series
This manual provides instructions for the Flowline Switch-Pak with Compact Relay Controller, available in AU13, AV13, and AZ13 series. The units are identical except for construction material, strobe alert type, and sensor technology (Ultrasonic, Buoyancy, or Vibration). It details specifications, components, safety precautions, and installation methods for in-tank or side-mount applications.
| Supply voltage | 120/240 VAC @ 50-60 Hz |
|---|---|
| Contact rating | 250 VAC @ 16A |
| Contact type | 1 SPDT relay |
| Process temperature (F) | -40 to 176 |
| Pressure (AU13/AZ13) | 150 psi (10 bar) |
| Pressure (AV13) | 25 psi (1.7 bar) |
| Enclosure rating | NEMA 4X (IP65) |
The available sensor technologies are Vibration (LZ12 series), Ultrasonic (LU10 series), and Buoyancy (LV10 series).
The Switch-Pak is designed for use in application temperatures up to 80° C (176° F).
Connect the supply to the COM terminal and the device to the NO or NC terminal as required.