Flowline LV41 & LV42 Series Sump Float Level Switches Manual

This document introduces the features and characteristics of Flowline, Inc.'s Switch-Tek™ Sump Float Level Switches LV41 & LV42 Series products, including models, functions and applications.


Flowline LV41 & LV42 Series Sump Float Level Switches Manual - cover page
Brand
FlowLine
Category
Other Electronics
Document type
User Manual
Language
English
Pages
10
File format
PDF
File size
217 KB
Published
12 October, 2023
Updated
12 October, 2023
MD5 checksum
CBCD69C3FA64453C4BD996F2F2CCEBC5

About this manual

This manual covers the Switch-Tek LV41 and LV42 series sump float level switches manufactured by Flowline. The LV41 series is a mercury-free mechanically actuated floating switch intended for simple level control of liquids, while the LV42 series is a self-counterweighted switch designed specifically for sewage water applications. Both series are mercury-free and feature polypropylene housings.

What's inside

  • Introduction
  • Specifications
  • Safety Precautions
  • Components
  • Installation
  • Wiring
  • Maintenance
  • Cleaning Procedure

Specifications

Wetted MaterialsHousing: Polypropylene, Cable: PVC
Temperature LimitsLV41: 32 to 122°F (0 to 50°C), LV42: -4 to 122°F (-20 to 50°C)
Pressure LimitsLV41: 14.5 psi (1 bar), LV42: 29 psi (2 bar)
Enclosure RatingIP68
Switch TypeSPDT (NO/NC)
Electrical RatingLV41: 10 (8) A@ 250 VAC, LV42: 10(3) A @ 250 VAC

Frequently asked questions

Are the LV41 and LV42 series switches mercury-free?

Yes, both the LV41 and LV42 series are mercury-free mechanically actuated floating switches.

Is the LV42 series suitable for sewage water?

Yes, the LV42 series body is designed for sewage water applications and is free of irregularities.

Can the LV42 series be used without a counterweight?

Yes, the LV42 series is self counterweighted and can be used without the need for an additional counterweight.