XMT7110 Intelligent PID Temperature Controller

The XMT7110 intelligent PID temperature controller is compatible with multiple temperature signals and can achieve time proportion PID control and upper and lower limit alarm or position control. The instrument has a self-tuning function and can display temperature values in Celsius or Fahrenheit.


XMT7110 Intelligent PID Temperature Controller - cover page
Brand
XMT
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
351 KB
Published
24 March, 2023
Updated
27 September, 2023
MD5 checksum
8E94C5644090B9404EBE5036AFFBF61E

About this manual

The document describes the XMT MT7110 intelligent PID temperature controller, detailing its technical specifications such as power supply requirements, sampling rate, and measurement accuracy. It supports various input signals including thermocouples (K, E, J, etc.) and resistance thermometers (Pt100, Cu50).

The guide explains how to configure the device using the front panel keys for functions like PID control, auto-tuning, alarm settings, and sensor type selection. It also includes a wiring diagram and a specific application example for controlling an oven temperature. This manual is written in Chinese.

What's inside

  • Main Technical Specifications
  • Panel Description
  • Parameter Setting (Initial Functions)
  • PID Control Parameters
  • Temperature Setpoint and Alarm Settings
  • Auto-Tuning Function
  • Terminal Diagram
  • Application Example

Specifications

Power SupplyAC85~260V/DC85~360V
Power Consumption< 2W
Sampling Rate4 times/second
Measurement Accuracy0.2%FS
Display Range-1999~9999
Dimensions72 x 36 x 75 mm

Frequently asked questions

How do I enter the initial function parameters?

Press SET, then input the password '0089' to access the initial settings.

What is the operating voltage range for this controller?

The device operates on AC power between 85 and 260V or DC power between 85 and 360V.

What is the maximum temperature display range?

The instrument can display temperatures from -1999 to 9999 degrees.

How many times per second does the controller sample data?

The sampling rate is set to 4 times per second.

Download PDF (351 KB)