UT UT-5508 Data Acquisition Module User Manual

UT-5508 is a data acquisition module used for collecting analog input. It is designed with industrial-grade high standards and uses automotive-grade MCU. It has 8 channels of differential analog input, each channel with 8 independent selectable range settings. It has hardware bandpass filtering and software filtering processing for signal, and the analog resolution is up to 24 bits. The module supports MODBUS-RTU communication protocol and is suitable for industrial field control, remote monitoring and data acquisition, power communication, rail transportation, ship electronics, heavy machinery, electronic product manufacturing, etc.


UT UT-5508 Data Acquisition Module User Manual - cover page
Brand
UT
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
823 KB
Published
18 January, 2023
Updated
28 September, 2023
MD5 checksum
9F96D305ADCE44EC41E5F2614EDB67F2

About this manual

The UT UT-5508 is an industrial-grade data acquisition module designed for analog input. It features 8 differential input channels, each with independently configurable ranges, and utilizes a 24-bit AD sampling resolution. The module supports the MODBUS-RTU communication protocol via an RS485 interface and is suitable for industrial control, remote monitoring, and data acquisition in various environments. This manual is written in Chinese.

What's inside

  • Overview
  • Technical Specifications
  • Indicator Lights
  • Pin Information
  • Code Table
  • Factory Parameters
  • Block Diagram
  • Wiring Diagrams
  • Communication Protocol

Specifications

Input Channels8 channels differential input
Resolution24-bit AD sampling
Communication ProtocolMODBUS-RTU
InterfaceRS485
Operating Voltage12-24V DC ±20%
Operating Temperature-20~+75℃
Isolation Voltage2500VDC

Frequently asked questions

What are the available input ranges for the UT-5508?

The module supports ranges of ±10V, ±5V, ±20mA, ±1V, ±500mV, and ±150mV.

What is the sampling frequency of the module?

The sampling frequency is 10Hz.

How many physical addresses can be assigned to the device?

The physical address range is from 1 to 247.