Shandong Renke RS-GZ Series Illuminance Transmitter User Manual

This document is the user manual of the analog type illuminance transmitter produced by Shandong Renke Measurement & Control Technology Co., Ltd. It introduces the features and characteristics of the product, including high-precision illuminance detection, multiple options for analog output signals, wall-mounted waterproof shell, and wide voltage power supply.


Shandong Renke RS-GZ Series Illuminance Transmitter User Manual - cover page
Brand
Shandong Renke
Category
sensor
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
619 KB
Published
19 November, 2022
Updated
28 September, 2023
MD5 checksum
A8A3C17651B4B5D4433FA13B2C66EBC8

About this manual

The document provides a user manual for the Shandong Renke RS-GZ series analog illuminance transmitter. It details the product's features, including high-precision detection with selectable ranges of 0-65,535 Lux or 0-200,000 Lux, and multiple analog output options (4-20mA, 0-5V, 0-10V). The device features a waterproof wall-mounted housing with an IP65 protection rating and supports a wide DC power supply of 10-30V. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Installation Instructions
  • Wiring Diagrams
  • Calculation Methods
  • Troubleshooting
  • Contact Information
  • Document History
  • Housing Dimensions

Specifications

Power Supply10-30V DC (24V for 0-10V models)
Protection RatingIP65
Measurement Range0-65,535 Lux or 0-200,000 Lux
Accuracy±7% (at 25°C)
Operating Temperature-40°C to +60°C
Response Time0.1s

Frequently asked questions

What is the power supply requirement for the 0-10V model?

The 0-10V model requires a DC 24V power supply.

What is the operating voltage range for this illuminance transmitter?

The device operates on a DC power supply ranging from 10V to 30V.

What is the maximum light intensity range available for this transmitter?

The measurement range can be selected as either 0 to 60,000 Lux or 0 to 200,000 Lux.

What is the response time of the illuminance sensor?

The device has a response time of 0.1 seconds for light intensity measurements.