This document introduces the application areas and advantages of the universal bracket CYH 101 and the economical bracket CYA 611 for the TI 092C/07/zh and TI 166C/07/zh analyzers and probes installation. The bracket can be used for installation in vertical columns of open channels, water pools, or tanks, and is suitable for pH/redox, dissolved oxygen, conductivity, and turbidity measurements. The hanging installation of the bracket enhances the self-cleaning effect of the sensors and allows for optimization of the measurement point by rotating the cross pipe and raising or lowering the immersion chain.
This document details the installation and technical data for the CYH101 universal vibration mount and the CYA611 PVC immersion mount. The CYH101 is designed for mounting sensors on vertical columns in applications like wastewater treatment and neutralization tanks, supporting various Endress+Hauser sensors including DipFit models. The CYA611 is an immersion mount bracket suitable for measuring dissolved oxygen, pH, and redox potential in wastewater, sewage pipes, and rivers, featuring a spray cleaning option. This manual is written in Chinese.
| Vertical Column Material | Stainless Steel AISI 304 |
|---|---|
| Operating Temperature | 0...60°C |
| Maximum Immersion Depth | Approx. 1400 mm |
| Tube Diameter / Wall Thickness | 40 mm / 3mm |
| Mounting Thread | 1" G or NPT 3/4" |
| Column Height | 1495 mm |
| Weight (Vertical Column) | 6kg |
The CYH101 is used for measuring dissolved oxygen, pH, and redox potential in applications such as wastewater treatment inlet/outlet, activated sludge tanks, and neutralization tanks.
The CYH101 supports DipFit sensors such as WCPA 111, CPA 510, CPA 530, WCLA 111, as well as dissolved oxygen sensors like WCOS 31 and WCOS 41.
The maximum immersion depth for the CYA611 bracket is approximately 1400 mm.