Aosong AM2306 Digital Humidity and Temperature Sensor User Manual


Aosong AM2306 Digital Humidity and Temperature Sensor User Manual - cover page
Brand
AOSONG
Category
sensor
Document type
User Manual
Language
Chinese
Pages
9
File format
PDF
File size
1.4 MB
Published
09 October, 2022
MD5 checksum
84E997097570C7F7838AE535985D7064

About this manual

The Aosong AM2306 is a digital humidity and temperature sensor module that outputs calibrated digital signals. It combines a capacitive humidity sensing element with a high-precision temperature sensing element connected to an 8-bit microcontroller. The sensor features a standard single-wire interface, low power consumption, and a signal transmission distance of up to 20 meters, making it suitable for various applications including medical and meteorological stations.

The document details the sensor's performance characteristics, including a relative humidity range of 0-99.9% RH with ±2% accuracy and a temperature range of -40 to 125°C with ±0.3°C accuracy. It also explains the single-wire communication protocol, pin definitions, and provides examples for calculating humidity and temperature values from the received data stream. This manual is written in Chinese.

What's inside

  • Product Overview
  • Application Range
  • Sensor Performance
  • Electrical Characteristics
  • Single-Wire Interface Definition
  • Single-Wire Communication Protocol
  • Data Calculation Examples
  • Communication Timing

Specifications

Relative Humidity Range0-99.9 %RH
Relative Humidity Accuracy±2 %RH
Temperature Range-40 to 125 °C
Supply Voltage3.3V - 5.5V
Signal Transmission Distance20 meters

Frequently asked questions

What is the recommended supply voltage for the AM2306?

The recommended supply voltage is 5V, although the operating range is 3.3V to 5.5V.

How long must the interval be between reading sensor data?

The minimum interval between readings should be greater than 2 seconds to ensure accurate data.

What is the resolution of the humidity sensor?

The resolution of the relative humidity sensor is 0.1 %RH.