AOSONG HR202L Humidity-Sensitive Resistor User Manual

This document is the product manual for HR202L humidity-sensitive resistor. It introduces the features and characteristics of the product, including wide humidity range, fast response, strong pollution resistance, etc. The product is suitable for applications such as temperature and humidity display meters, temperature and humidity gift watches, atmospheric environment monitoring, industrial process control, agriculture, and measurement instruments.


AOSONG HR202L Humidity-Sensitive Resistor User Manual - cover page
Brand
AOSONG
Category
sensor
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
5.7 MB
Published
29 September, 2022
Updated
28 September, 2023
MD5 checksum
ACBA936F55B8BE15CBB246E66A85E3E4

About this manual

The AOSONG HR202L is a new type of humidity-sensitive component made of organic high molecular materials. It features high sensitivity, fast response, strong anti-contamination ability, and does not require cleaning before use. The device is designed for use in temperature and humidity display instruments, data recorders, atmospheric environment monitoring, industrial process control, and measurement instruments. This manual is written in Chinese.

What's inside

  • Product Overview
  • Dimensions
  • Application Areas
  • Product Highlights
  • Circuit Diagram
  • Product Parameters
  • Calibration Conditions
  • Relative Humidity-Impedance Characteristics
  • Example Code
  • Copyright and Warnings

Specifications

Rated Voltage1.5V AC (Max sine wave)
Rated Power0.2mW (Max, sine wave)
Operating Frequency500Hz-2kHz
Operating Temperature0 to 60°C
Operating HumidityBelow 95% RH
Hysteresis< 2% RH
Response Time (Adsorption)< 20s
Stability< 1% RH/year
Humidity Measurement Accuracy< ±5% RH

Frequently asked questions

What are the main application areas for the HR202L?

It is used for temperature and humidity display instruments, data recorders, atmospheric environment monitoring, industrial process control, and measurement instruments.

Does the HR202L require cleaning before use?

No, it does not require cleaning before use.

What is the rated voltage and power for the HR202L?

The rated voltage is 1.5V AC (Max sine wave) and the rated power is 0.2mW (Max, sine wave).

What is the operating temperature range?

The operating temperature range is from 0 to 60°C.

Download PDF (5.7 MB)